E L A N H O M E S Y S T E M S
© ELAN Home Systems 2009 All rights reserved. Page 23
A6 INSTALLATION MANUAL
Table 5-3: IR Control
Symptom Possible Cause Solution
IR LED does NOT flash
when a button pressed.
1. IR controller not programmed.
2. IR signal path wiring bad.
Program IR controller.
Verify IR signal path wiring.
Check keypads, IR sensors, IR
distribution blocks, IR Input
jack, IR emitters, etc.
No channel selected
from IR controller.
IR LED DOES flash when
button pressed.
1. Incorrect IR commands
programmed).
2. Chassis codeset incorrect.
Verify/correct IR programming.
Verify/correct IR programming.
Intermittant or no control from IR con-
troller. IR LED on LCD flickers or is lit
constantly.
IR flooding. Check IR receivers for ambient light or
plasma TV flooding.
Technical Support
If, after carefully following the steps in the Troubleshooting section, you are
unable to resolve issues with the installation or operation of the A6, please call
ELAN Technical Support at 1-800-622-ELAN (3526).